<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-08 05-00-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 50 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
3 kHz 35 kHz 18999 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-4,6 dBr -1,93 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 5:00, 8.04.2024
RT
"Cesky rozhlas Vysocina - zijeme tu s vami "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 35 kHz MIN: 3 kHz % above 77 kHz: 0,0000 Acquired: 2024/04/08 5:00:16 Total samples: 18999 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,2 dBr MIN: -4,6 dBr AVE: -1,93 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2024/04/08 5:00:16) 04:46 04:48 04:50 04:52 04:54 04:56 04:58 05:00 -5 0 Pm [dBr] 0 5 Signal Quality